How to solve pressure switch display problem
From: Issued date 2020.02.17 Back
1. Wotian visits a large customer’s company
Recently, Wotian received a feedback from a large customer about pressure switch PCM710. It has been displayed on the meter after power-on, but the value displayed does not change after adding pressure (pressure is changing).
2. Wotian visits a large customer’s company
WoTian urgently sends a research and development team to the site to investigate the problem and find out the reasons.
3. Wotian investigates on site
4. Wotian adjusts on site
After a series of tests and research, Wotian discovers the reason. When the motor is energized, a magnetic field is generated, and the generated magnetic field will interfere with the pressure switch operation, resulting in abnormality of the pressure switch.
5. Wotian product application
After finding this conclusion, Wotian formulates an improvement plan to enhance the anti-interference ability of the product, and improves the EMC (Electro Magnetic Compatibility) anti-interference level so that the product can be used normally.
6. Wotian product application
Wotian adheres to “creating value for customers”, continuously learning and progressing, reflecting on customer feedback, constantly updating and improving products. Wotian is responsible for trust, lean creation and going all the way.